Roof
Assembly, covering, and remaining useful life, the component most likely to drive the near-term funding number.
Florida condominium associations three stories or more must commission a Structural Integrity Reserve Study by their statutory deadline. Edison coordinates the engineer, manages the deliverable, and helps your board build a funding plan that meets the mandate.
A Structural Integrity Reserve Study is a Florida-specific reserve assessment created by Senate Bill 4D after the Champlain Towers South collapse. It applies to condominium and cooperative buildings three stories or more, and it requires a licensed engineer or architect to inventory and price the remaining useful life of eight specific structural and life-safety components, roof, load-bearing walls, floor, foundation, fireproofing, plumbing, electrical, and waterproofing.
A SIRS is not interchangeable with a traditional reserve study. The traditional reserve study covers a broader set of community assets, pools, paving, clubhouses, amenity replacements, but isn't sufficient on its own under FL Ch. 718. Most associations now need both: a SIRS for statutory compliance, and a comprehensive reserve study for full capital planning. Edison coordinates both, sequences them, and translates the engineering findings into a fundable plan.
Boards routinely ask how the SIRS relates to the milestone inspection, because SB-4D created both. The milestone inspection answers a condition question: is the structure sound today? The SIRS answers a money question: what will those structural components cost to maintain and replace, and what does the association need to bank each year to get there. They are usually sequenced, milestone first, SIRS second, so the reserve numbers reflect what the engineer actually found on the building.
The compliance dates have moved more than once. The original SB-4D deadline for existing buildings was December 31, 2024, and subsequent legislative sessions extended relief to associations whose milestone inspection was due at the end of 2024, pushing them to December 31, 2025. Both dates are now behind us. An association without a completed SIRS is not exempt, it is behind on a statutory obligation the board has a fiduciary duty to remedy, and Edison's intake starts by confirming exactly which deadline applied to your building. For the broader picture of how reserve studies work in Florida, our reserve study guide for Florida boards covers the fundamentals.
Boards are often told they already have "a reserve study." Under Ch. 718, that answer is usually incomplete. Here is where the two actually diverge.
Every SIRS engagement covers these components at minimum. The engineer may add anything else with a deferred maintenance or replacement cost above the statutory threshold that bears on structural integrity.
Assembly, covering, and remaining useful life, the component most likely to drive the near-term funding number.
Load-bearing walls and other primary structural members, assessed for condition and remaining life.
Floor structure and slabs, including the deterioration patterns coastal buildings see first.
Foundation systems, evaluated against the building's settlement, drainage, and water-intrusion history.
Fireproofing and fire protection systems, a life-safety component boards frequently under-reserve.
Supply, waste, and vertical stack systems, where age-based repiping decisions get expensive fast.
Electrical systems, including distribution equipment that predates current code expectations.
Waterproofing and exterior painting where related to structure, the recurring cycle that protects everything above.
Edison doesn't perform the engineering. We handle everything around it: engineer selection, scope review, document coordination, board presentation, and the post-study funding plan.
Edison sources 3+ qualified Florida-licensed structural engineers and helps the board select on scope and credentials, not just price.
Historical inspection records, building permits, prior reserve studies, and capital expenditure history assembled for the engineer.
Resident notification, common-area access, vendor coordination, and roof/equipment access scheduling.
Edison's accounting team reviews the draft against actual capital history and flags discrepancies for revision before final issuance.
Board-friendly summary of findings, what's failing, what's funded, what's not, plus a recommended funding strategy.
SIRS components integrated into the annual budget, reserve banking strategy, and 5-year capital plan.
From engineer selection through board adoption, usually 90–150 days end to end.
Edison reviews governing documents, building age, last reserve study, and SB-4D filing status. Statutory deadline confirmed.
Three competing bids from FL-licensed engineers. Board approves; Edison handles contracting and access.
Engineer performs site work. Edison reviews the draft and coordinates revisions before the final is issued.
Findings presented with a recommended funding plan. Plan integrated into the next annual budget.
Edison's first conversation is free. We'll review your association's status against Ch. 718 / SB-4D requirements and tell you exactly where you stand.
Tell us what you know about your building's status. We'll respond with what's required, what it costs, and how to sequence it, within one business day.